Pre-engineer Condensing Gas Oil Fired Steam Boiler

Pre-engineer Condensing Gas Oil Fired Steam Boiler

Steam Capacity Range: 0.5-6 ton/hour, 30-400BHP
Fuel Options: Natural Gas, LPG, LNG, Biogas, Diesel, Heavy Oil, Dual Fuel , Propane , #2 Fuel Oil
Steam Pressure: 1.0MPA-3.82MPA
Key Features:

Fast steam generation within 2-3 minutes.

External steam-water separator, steam dryness >99%

Skid-mounted steam boiler system, save installation cost, easy move.

Coil pipe structure, wide pressure range up to 3.82Mpa

Condensing type, 5% higher efficiency than one-though boiler, save fuel cost

Advantage

  • Brief introduction:

    This condensing steam boiler is newly developed by Kenuo boiler, has the features of small water volume, safe and reliable performance. It adopted unique and durable coil structure, inner circulation created super low pressure diffierence, and smaller thermal stress shock,higher heat efficiency and longer service life. Equipped with intellegent controller can realize boiler fullly automatic control.

    The whole steam boiler system is mounted on skid or in a container, make it easy move from one place to other place. The installation work are undertaken by manufacturer and finish the commissioning in factory before delivery. When the boiler arrive your work site, it can be put in to use soon after connect to water, electricity and fuel supply.

  • Features:

    1.Lower Water quality requirements. Different from traditional water tube steam boiler, Kenuo boiler uses counter-current heat exchange forced circulation technology and high-speed water flow to make the coil less prone to scaling.

    2.Fast steam generation, it takes only 2-3 minutes to reach the required working pressure.

    3.Adopt coil structure, high thermal efficiency and long service life.

    4.Highly integrated structure with burner, controller, condenser, water pump all in one machine, smallest size, save boiler construction investment.

    5.Intelligent power-save automatic control (water replenishment as required and stable pressure)

    Adopt Swiss brand ADD inverter, perfect combination with combustion fan , feed water pump, and optimized PLC automatic control, boiler load meets the full-proportional personalized output. Wide frequency conversion makes the motor output more power-saving, energy-saving and stepless adjustment.

Working Principle

  • Working Principle
  • Water System Diagram
Working Principle
Water System Diagram

Parameters

Model

Rated steam output(TPH)

Rated working pressure(MPA)

Rated Steam Temperature(℃)

Heat Efficiency(%)

Nox Emission(mg/m³)

Transportation Weight(ton)

Overall Dimension(mm)

PGS0.5-0.8-Y(Q)

0.5

0.8

175

≥101

≤80 or ≤30

1.4

2100*1500*2200

PGS1-1.25-Y(Q)

1

1.25

194

≥101

≤80 or ≤30

2.6

2500*1700*2800

PGS1.5-1.25-Y(Q)

1.5

1.25

194

≥101

≤80 or ≤30

3.5

2800*1900*3000

PGS2-1.25-Y(Q)

2

1.25

194

≥101

≤80 or ≤30

4.8

3400*2200*3300

PGS3-1.25-Y(Q)

3

1.25

194

≥101

≤80 or ≤30

6.5

3600*2400*3500

PGS4-1.25-Y(Q)

4

1.25

194

≥101

≤80 or ≤30

8.7

3800*2500*3600

PGS5-1.25-Y(Q)

5

1.25

194

≥101

≤80 or ≤30

10.4

4000*2700*3800

PGS6-1.25-Y(Q)

6

1.25

194

≥101

≤80 or ≤30

11.3

4000*2700*3800

PGS8-1.25-Y(Q)

8

1.25

194

≥101

≤80 or ≤30

14.5

4300*30000*4100

PGS10-1.25-Y(Q)

10

1.25

194

≥101

≤80 or ≤30

18.2

4600*3000*4300

Video

Send Massage

Home Tel Product Inquiry